Fault location of HVDC transmission line via IPOA-LSSVM model
Author:
Clc Number:

TM755

  • Article
  • | |
  • Metrics
  • |
  • Reference [15]
  • |
  • Related [19]
  • | | |
  • Comments
    Abstract:

    Fault location is crucial for the long-distance HVDC transmission systems.Here,a fault location model using the Improved Pelican Optimization Algorithm (IPOA) to optimize the Least Squares Support Vector Machine (LSSVM) is provided to address the issues of imprecise attenuation coefficient computation and challenging secondary wave head capture.First,in accordance with the traveling wave attenuation concept,the formulas of the fault distance and the modulus maximum ratio of the line mode components at both ends of the line are derived,revealing a nonlinear relationship between them,which is then generalized by LSSVM.Second,the IPOA is employed to optimize the key parameters of LSSVM,thereby constructing the IPOA-LSSVM fault location model.After performing wavelet transform on the fault signals collected at both ends,the amplitude ratio of the first wave head is obtained and then input into the proposed model to output the fault distance as simulation verification.Simulation results show that the proposed model can locate fault reliably and accurately regardless of transition resistance and fault type.

    Reference
    [1] 雷朝煜,郝良收,戴甲水,等.高压直流输电线路故障定位研究综述[J].电力系统保护与控制,2022,50(11):178-187 LEI Zhaoyu,HAO Liangshou,DAI Jiashui,et al.A review of fault location methods in HVDC transmission lines[J].Power System Protection and Control,2022,50(11):178-187
    [2] 段建东,刘静,陆海龙,等.基于行波瞬时频率的高压直流输电线路故障测距方法[J].中国电机工程学报,2016,36(7):1842-1848 DUAN Jiandong,LIU Jing,LU Hailong,et al.Fault location method based on traveling-wave instantaneous frequency for HVDC transmission lines[J].Proceedings of the CSEE,2016,36(7):1842-1848
    [3] 任红向,梁睿,丁然,等.双端非同步数据精确线搜索比相的故障定位[J].电网技术,2015,39(10):2972-2978 REN Hongxiang,LIANG Rui,DING Ran,et al.Fault location research adopted two-terminal asynchronous data and based on accurate line-searching and phase-comparing[J].Power System Technology,2015,39(10):2972-2978
    [4] Reis R L A,Lopes F V,Neves W L A,et al.An improved single-ended correlation-based fault location technique using traveling waves[J].International Journal of Electrical Power & Energy Systems,2021,132:107167
    [5] He Z Y,Liao K,Li X P,et al.Natural frequency-based line fault location in HVDC lines[J].IEEE Transactions on Power Delivery,2014,29(2):851-859
    [6] Liang Y S,Wang G,Li H F.Time-domain fault-location method on HVDC transmission lines under unsynchronized two-end measurement and uncertain line parameters[J].IEEE Transactions on Power Delivery,2015,30(3):1031-1038
    [7] Johnson J M,Yadav A.Complete protection scheme for fault detection,classification and location estimation in HVDC transmission lines using support vector machines[J].IET Science,Measurement & Technology,2017,11(3):279-287
    [8] Lan S,Chen M J,Chen D Y.A novel HVDC double-terminal non-synchronous fault location method based on convolutional neural network[J].IEEE Transactions on Power Delivery,2019,34(3):848-857
    [9] Luo G M,Yao C Y,Liu Y L,et al.Stacked auto-encoder based fault location in VSC-HVDC[J].IEEE Access,2018,6:33216-33224
    [10] 陈仕龙,张杰,毕贵红,等.一种基于高频量衰减特性的特高压直流输电线路故障测距方法[J].电力系统保护与控制,2014,42(10):77-83 CHEN Shilong,ZHANG Jie,BI Guihong,et al.A fault location method based on high frequency attenuation characteristic of UHVDC transmission line[J].Power System Protection and Control,2014,42(10):77-83
    [11] 宋国兵,侯俊杰,郭冰.基于主动探测式的混合MMC直流输电系统单端量故障定位[J].电网技术,2021,45(2):730-740 SONG Guobing,HOU Junjie,GUO Bing.Single-ended fault location of hybrid MMC-HVDC system based on active detection[J].Power System Technology,2021,45(2):730-740
    [12] 陈仕龙,束洪春,谢静,等.特高压直流输电线路和边界频率特性研究[J].电力自动化设备,2013,33(11):134-139,153 CHEN Shilong,SHU Hongchun,XIE Jing,et al.Frequency characteristics of UHVDC transmission line and its boundary[J].Electric Power Automation Equipment,2013,33(11):134-139,153
    [13] 邢超,高敬业,毕贵红,等.基于集成神经网络的特高压直流输电线路初始电压行波小波变换模极大值比单端测距方法[J].电力自动化设备,2022,42(11):128-134 XING Chao,GAO Jingye,BI Guihong,et al.Single-end fault location method used ratio between WT modulus maximum values of initial voltage traveling wave for UHVDC transmission line based on integrated neural network[J].Electric Power Automation Equipment,2022,42(11):128-134
    [14] 李云淏,咸日常,张海强,等.基于改进灰狼算法与最小二乘支持向量机耦合的电力变压器故障诊断方法[J].电网技术,2023,47(4):1470-1478 LI Yunhao,XIAN Richang,ZHANG Haiqiang,et al.Fault diagnosis for power transformers based on improved grey wolf algorithm coupled with least squares support vector machine[J].Power System Technology,2023,47(4):1470-1478
    [15] Trojovsky P,Dehghani M.Pelican optimization algorithm:a novel nature-inspired algorithm for engineering applications[J].Sensors,2022,22(3):855
    Cited by
Get Citation

SHANG Liqun, LIU Han, HAO Tianqi, LI Zhao, LI Chaobiao, DENG Liwen. Fault location of HVDC transmission line via IPOA-LSSVM model[J]. Journal of Nanjing University of Information Science & Technology,2024,16(5):667-677

Copy
Share
Article Metrics
  • Abstract:28
  • PDF: 144
  • HTML: 26
  • Cited by: 0
History
  • Received:October 09,2023
  • Online: October 30,2024
  • Published: September 28,2024
Article QR Code

Address:No. 219, Ningliu Road, Nanjing, Jiangsu Province

Postcode:210044

Phone:025-58731025