  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对超级电容传统静态参数等效电路模型不能有效反映其动态工作特性问题,提出一种包含动态充放电内阻和电容参数的二阶梯形等效电路模型,利用递推最小二乘法对二阶梯形等效电路模型参数进行初步离线辨识。进一步,考虑超级电容参数的动态变化,将离线辨识模型参数作为初值,引入带遗忘因子的递推最小二乘法对动态参数进行实时辨识。搭建超级电容仿真模型和实验测试平台,通过仿真和实验结果对比验证动态参数二阶梯形等效电路模型和实时辨识方法的有效性和准确性。结果表明:动态参数二阶梯形等效电路模型可以有效反映超级电容的动态充放电工作特性,与传统静态参数的三分支等效电路模型和二阶梯形等效电路模型相比,模型的精度分别提高2.08%和3.56%以上。

    Abstract:

    In view of the problem that the traditional static parameter equivalent circuit model of the supercapacitor cannot effectively reflect its dynamic operating characteristics, a second-order ladder equivalent circuit model including dynamic charge/discharge resistance and capacitance parameters is proposed. The recursive least square method is used for the offline parameter identification of the second-order ladder equivalent circuit model at first. Furthermore, by considering the dynamic change of the supercapacitor parameters, the offline identified model parameters are used as initial values. Then, the recursive least square method with forgetting factor is introduced to identify the dynamic parameters of supercapacitor in real-time. Simulation model and experimental test platform of the supercapacitor are established. On this basis, the effectiveness and accuracy of the second-order ladder equivalent circuit model with dynamic parameters and the real-time identification method are verified through the comparison of simulation and experimental results. Results show that the second-order ladder equivalent circuit model with dynamic parameters can effectively reflect the dynamic charge/discharge operating characteristics of the supercapacitor. Compared with the traditional three branch and second-order ladder equivalent circuit models with static parameters, the model accuracy is improved over 2.08% and 3.56%, respectively.

    参考文献
    相似文献
    引证文献
引用本文

高全成,王帅,周国威,王斌,李丽霞.超级电容动态参数等效电路模型及实时辨识方法[J].南京信息工程大学学报,,():

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2022-12-05
  • 最后修改日期:2022-12-26
  • 录用日期:2023-01-03
  • 在线发布日期:
  • 出版日期:

地址:江苏省南京市宁六路219号    邮编:210044

联系电话:025-58731025    E-mail:nxdxb@nuist.edu.cn

南京信息工程大学学报 ® 2024 版权所有  技术支持:北京勤云科技发展有限公司